Description:
The Banner-Day externally mounted Safe-DD™ dual disconnect is a compact panel containing two fused disconnects (primary and lighting), a control transformer and appropriately sized fusing. The main disconnect is responsible for feeding the primary power to the main control panel. The secondary lighting disconnect, wired in parallel to the main disconnect, provides power to the lighting circuit. This parallel wiring is designed specifically so the main power may be locked out separately, while maintaining an active lighting circuit. The lighting circuit is intended to power various light sources (both inside the main panel and on the machine) and allow the PLC and HMI devices to remain active. This capability can be especially useful during machine installation/startup and when modifications are made, as it allows the machine to be mechanically/electrically worked on in a safe manner while still allowing the debug of the PLC/HMI software.
Safe-DD™ Benefits:
- Main panel space savings
- Arc flash hazard reduction
- Maintenance convenience and time savings

Assembled Safe-DD™ Dual Disconnect ready for shipment